{"product_id":"mclimate-16a-switch-and-power-meter-mc-lw-16aspm-01","title":"MClimate 16A Switch and Power Meter","description":"\u003ch2\u003eMClimate 16A Switch \u0026amp; Power Meter LoRaWAN\u003c\/h2\u003e\n\u003cp\u003e\u003cem\u003eA Ready For Anything® building block for controllable, measurable electrical loads\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch3\u003eControl what you consume — and prove it with real power data.\u003c\/h3\u003e\n\u003cp\u003e MClimate 16A Switch \u0026amp; Power Meter LoRaWAN is a compact \u003cstrong\u003e16A relay and electricity meter\u003c\/strong\u003e designed for rapid retrofit projects where you want to automate, track, and control electrical appliances without rebuilding infrastructure.\n\u003c\/p\u003e\n\n\u003chr\u003e\n\n\u003ch2\u003eThe problem this product exists to solve\u003c\/h2\u003e\n\n\u003cp\u003e\nIn many buildings, electrical loads are either invisible at the right level of detail, or disconnected from the systems that operators actually use.\n\u003c\/p\u003e\n\n\u003cp\u003e\nThis leads to wasted energy, limited fault detection, reactive maintenance, and energy programmes that depend on assumptions rather than measurable outcomes.\n\u003c\/p\u003e\n\n\u003cp\u003e\nThe issue isn’t that buildings lack data.\nIt’s that the data is not collected in a scalable way, not integrated cleanly, and not connected to actions that reduce operational effort.\n\u003c\/p\u003e\n\n\u003cp\u003e\nWhen this is addressed properly, electrical systems become easier to operate, easier to optimise, and far more resilient over time.\n\u003c\/p\u003e\n\n\u003cdiv style=\"border:1px solid #e5e7eb; padding:16px; border-radius:12px; background:#f9fafb; margin:18px 0;\"\u003e\n  \u003cstrong\u003eNiagara Integration (Innon Support)\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\n  For Niagara-based systems, \u003cstrong\u003eMClimate 16A Switch \u0026amp; Power Meter LoRaWAN\u003c\/strong\u003e can be integrated using Innon’s \u003cstrong\u003eLoRaWAN driver for Niagara\u003c\/strong\u003e, allowing power and energy data — as well as relay state — to be exposed cleanly as native Niagara points.\u003cbr\u003e\u003cbr\u003e\n  \u003cul style=\"margin:0; padding-left:18px;\"\u003e\n    \u003cli\u003eConsistent point models across loads and sites\u003c\/li\u003e\n    \u003cli\u003eRepeatable deployment without fragile middleware\u003c\/li\u003e\n    \u003cli\u003eCleaner handover and easier long-term operation\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003chr\u003e\n\n\u003ch2\u003eWhy this product is Ready For Anything®\u003c\/h2\u003e\n\n\u003ch3\u003eReady for Today\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCombines a 16A relay with electricity metering in one compact device\u003c\/li\u003e\n  \u003cli\u003eEnables immediate on\/off control and visibility of electrical consumption\u003c\/li\u003e\n  \u003cli\u003eDesigned to be small enough to fit behind most wall switches and power equipment\u003c\/li\u003e\n  \u003cli\u003eSimple wiring model using 4 terminals: \u003cstrong\u003eL, N, N, Lout\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eReady for Tomorrow\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eLoRaWAN® \u003cstrong\u003eClass C\u003c\/strong\u003e operation supports faster command responsiveness than sleep-only devices\u003c\/li\u003e\n  \u003cli\u003eFirmware Upgrade Over The Air (FUOTA) supports future improvements and long lifecycle deployments\u003c\/li\u003e\n  \u003cli\u003eSuitable for scaling across rooms, floors, and multi-site rollouts\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eReady for Security\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOvercurrent, Overvoltage, and Overheating protection\u003c\/strong\u003e to reduce long-term operational risk and safeguard connected loads\u003c\/li\u003e\n  \u003cli\u003eDesigned for retrofit environments where reliability matters\u003c\/li\u003e\n  \u003cli\u003eLoRaWAN-based architectures help reduce dependency on local IP network exposure\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eReady for Integration\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOpen LoRaWAN® connectivity for multi-vendor system architectures\u003c\/li\u003e\n  \u003cli\u003eClean mapping of metering data and relay state into BMS platforms\u003c\/li\u003e\n  \u003cli\u003eSupported via Innon’s LoRaWAN driver for Niagara\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr\u003e\n\n\u003ch2\u003eWhat makes this product different\u003c\/h2\u003e\n\n\u003cp\u003e\nMany retrofits treat monitoring and control as separate projects: one device to measure, another to switch, and a lot of integration effort in between.\n\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eControl + measurement in one unit:\u003c\/strong\u003e switch the load and verify the impact using real metering data.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRetrofit-friendly form factor:\u003c\/strong\u003e compact enough to fit behind most wall switches and power equipment, avoiding cabinet rebuilds.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSimple, repeatable wiring:\u003c\/strong\u003e the relay works by connecting and disconnecting \u003cstrong\u003eLout\u003c\/strong\u003e from \u003cstrong\u003eL\u003c\/strong\u003e, making it easy to standardise across projects.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBuilt for operational resilience:\u003c\/strong\u003e Overcurrent, Overvoltage, and Overheating protection, combined with FUOTA, supports long-term reliability.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFaster responsiveness:\u003c\/strong\u003e LoRaWAN Class C supports quicker command handling compared with sleep-heavy devices.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\nThis makes MC-LW-16ASPM-01 ideal for practical energy optimisation and automation projects where outcomes must be measurable and repeatable.\n\u003c\/p\u003e\n\n\u003chr\u003e\n\n\u003ch2\u003eFrom good systems to great outcomes\u003c\/h2\u003e\n\n\u003cp\u003e\nMany buildings can see energy at a high level, but cannot act at the load level — or cannot prove the impact of control changes.\n\u003c\/p\u003e\n\n\u003cp\u003e\nUsed properly, MC-LW-16ASPM-01 enables:\n\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003eMeasured energy optimisation (switch + verify)\u003c\/li\u003e\n  \u003cli\u003eImproved fault detection through abnormal consumption patterns\u003c\/li\u003e\n  \u003cli\u003eReduced reactive maintenance and site visits\u003c\/li\u003e\n  \u003cli\u003eCleaner handover with control logic that remains understandable over time\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr\u003e\n\n\u003ch2\u003eHow this fits into a Ready For Anything® solution\u003c\/h2\u003e\n\n\u003cp\u003e\nOn its own, MC-LW-16ASPM-01 provides a building block for electrical load switching and metering.\n\u003c\/p\u003e\n\n\u003cp\u003e\nWhen combined with the right LoRaWAN architecture, Niagara integration, point modelling, and operational processes, it becomes part of a Ready For Anything® solution — designed to keep delivering value after commissioning.\n\u003c\/p\u003e\n\n\u003chr\u003e\n\n\u003ch2\u003eWho this product is for\u003c\/h2\u003e\n\n\u003cp\u003e\u003cstrong\u003eDesigned for\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSystem integrators delivering scalable automation and energy retrofits\u003c\/li\u003e\n  \u003cli\u003eFM and energy teams who need actionable load-level control\u003c\/li\u003e\n  \u003cli\u003eOwners focused on measurable performance and long-term optimisation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eNot ideal for\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eProjects driven purely by lowest upfront cost\u003c\/li\u003e\n  \u003cli\u003eDeployments with no plan for integration or operational use\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr\u003e\n\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eLoad control and energy metering behind wall switches\u003c\/li\u003e\n  \u003cli\u003eAutomation of electrical appliances with measurable outcomes\u003c\/li\u003e\n  \u003cli\u003eOut-of-hours shutdown strategies with verification\u003c\/li\u003e\n  \u003cli\u003eRetrofit programmes requiring fast, repeatable installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr\u003e\n\n\u003ch2\u003eTechnical details\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct type:\u003c\/strong\u003e 16A relay + electricity meter\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLoRaWAN mode:\u003c\/strong\u003e Class C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRetrofit wiring terminals:\u003c\/strong\u003e L, N, N, Lout (relay connects\/disconnects Lout from L)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eKey features:\u003c\/strong\u003e Overcurrent protection, Overvoltage protection, Overheating protection, FUOTA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInstallation note:\u003c\/strong\u003e Designed to fit behind most wall switches and power equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e LoRaWAN gateways, Niagara via Innon driver\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr\u003e\n\n\u003ch2\u003eDatasheet\u003c\/h2\u003e\n\u003cp\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1144\/2302\/files\/MClimate-16ASPM-Datasheet.pdf?v=1769678632\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\nDownload the MC-LW-16ASPM-01 datasheet\n\u003c\/a\u003e\n\u003c\/p\u003e\n\n\u003chr\u003e\n\n\u003ch2\u003eReady to discuss your project?\u003c\/h2\u003e\n\n\u003cp\u003e\nIf you’re planning a rapid retrofit automation or energy optimisation programme and want to understand how this fits into a wider \u003cstrong\u003eReady For Anything® solution\u003c\/strong\u003e, start a conversation with Innon.\n\u003c\/p\u003e\n\n\u003cscript src=\"https:\/\/js.hsforms.net\/forms\/embed\/5694023.js\" defer\u003e\u003c\/script\u003e\n\u003cdiv class=\"hs-form-frame\" data-region=\"na1\" data-form-id=\"8feb1a55-7168-493e-ad2b-28a7bbdb648e\" data-portal-id=\"5694023\"\u003e\u003c\/div\u003e\n","brand":"MClimate","offers":[{"title":"Default Title","offer_id":56519052263802,"sku":"MC-LW-16ASPM-01","price":71.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1144\/2302\/files\/MC-LW-16ASPM-01.png?v=1769679266","url":"https:\/\/www.innon.com\/en-de\/products\/mclimate-16a-switch-and-power-meter-mc-lw-16aspm-01","provider":"Innon Energy LTD","version":"1.0","type":"link"}