{"product_id":"mclimate-fan-coil-thermostat-mc-lw-fct","title":"MClimate FAN-COIL THERMOSTAT","description":"\u003ch2\u003eMClimate Fan Coil Thermostat LoRaWAN\u003c\/h2\u003e\n\u003cp\u003e\u003cem\u003eA Ready For Anything® building block for flexible, room-level fan coil control\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch3\u003eRoom-by-room comfort and control — built for retrofit reality.\u003c\/h3\u003e\n\u003cp\u003e\nThe MClimate Fan Coil Thermostat (FCT) is a LoRaWAN® thermostat for 2- and 4-pipe Fan Coil Units, supporting 1–3 speed or ECM fans. It is designed for building retrofitting and enables room-by-room monitoring and control to improve energy efficiency and reduce heating\/cooling expenses.\n\u003c\/p\u003e\n\n\u003chr\u003e\n\n\u003ch2\u003eThe problem this product exists to solve\u003c\/h2\u003e\n\n\u003cp\u003e\nIn many buildings, fan coil units are controlled by aging thermostats that offer limited visibility, poor integration, and little flexibility after handover.\n\u003c\/p\u003e\n\n\u003cp\u003e\nThis leads to inefficient heating and cooling, high energy costs, occupant discomfort, and facilities teams forced to rely on manual intervention.\n\u003c\/p\u003e\n\n\u003cp\u003e\nThe issue isn’t fan coil technology.\nIt’s the lack of room-level control that is easy to retrofit, easy to integrate, and resilient to change.\n\u003c\/p\u003e\n\n\u003cp\u003e\nWhen this problem is addressed properly, buildings gain better comfort control, lower energy consumption, and systems that remain usable long after commissioning.\n\u003c\/p\u003e\n\n\u003cdiv style=\"border:1px solid #e5e7eb; padding:16px; border-radius:12px; background:#f9fafb; margin:18px 0;\"\u003e\n  \u003cstrong\u003eNiagara Integration (Innon Support)\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\n  For Niagara-based systems, \u003cstrong\u003eMClimate Fan Coil Thermostat LoRaWAN\u003c\/strong\u003e can be integrated using Innon’s \u003cstrong\u003eLoRaWAN driver for Niagara\u003c\/strong\u003e, allowing temperature, humidity, setpoints, modes, and fan states to be exposed cleanly as native Niagara points.\u003cbr\u003e\u003cbr\u003e\n  \u003cul style=\"margin:0; padding-left:18px;\"\u003e\n    \u003cli\u003eConsistent point models across rooms and sites\u003c\/li\u003e\n    \u003cli\u003eReduced integration time and fewer one-off mappings\u003c\/li\u003e\n    \u003cli\u003eCleaner handover and long-term operability\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003chr\u003e\n\n\u003ch2\u003eWhy this product is Ready For Anything®\u003c\/h2\u003e\n\n\u003ch3\u003eReady for Today\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCompatible with 2-pipe and 4-pipe FCUs and supports 3-speed or ECM fans\u003c\/li\u003e\n  \u003cli\u003eBuilt-in temperature and humidity sensors\u003c\/li\u003e\n  \u003cli\u003e4.2” fast-refresh e-ink display for clear local control and visibility\u003c\/li\u003e\n  \u003cli\u003eSimple 4-button interface (ON\/OFF\/Mode, Increase temp, Decrease temp, Select fan speed)\u003c\/li\u003e\n  \u003cli\u003eAnti-theft stainless steel bracket with secure screw (T5 Torx)\u003c\/li\u003e\n\u003cli\u003eConfigurable key lock — select which keys are disabled to prevent unauthorised adjustment of settings, fan speed, or temperature\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eReady for Tomorrow\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eLoRaWAN® Class C device enables real-time communication (receives commands in real time)\u003c\/li\u003e\n  \u003cli\u003eFirmware Upgrade Over The Air (FUOTA)\u003c\/li\u003e\n  \u003cli\u003eSupports additional inputs\/outputs such as occupancy\/keycard input, auto-changeover NTC, dew point sensor, filter alarm\u003c\/li\u003e\n  \u003cli\u003eInstaller’s menu supports wiring configuration selection and settings\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eReady for Security\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eLoRaWAN® end-to-end encryption (AES-CTR)\u003c\/li\u003e\n  \u003cli\u003eMains-powered operation (110–240VAC) avoids battery lifecycle risk\u003c\/li\u003e\n  \u003cli\u003eIP31 enclosure (indoor use)\u003c\/li\u003e\n  \u003cli\u003eAnti-theft bracket with secure screw (T5 Torx)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eReady for Integration\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eFully open and transparent communication protocol\u003c\/li\u003e\n  \u003cli\u003eCompatible with BMS\/BAS integrations (via LoRaWAN-to-BMS gateway approaches) and MClimate Enterprise\u003c\/li\u003e\n  \u003cli\u003eSupported via Innon’s LoRaWAN driver for Niagara for repeatable, scalable deployments\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr\u003e\n\n\u003ch2\u003eFrom good systems to great outcomes\u003c\/h2\u003e\n\n\u003cp\u003e\nMany fan coil installations stop at basic on\/off control and manual adjustment.\nUsed properly, MC-LW-FCT-01 enables room-level optimisation and operational control that remains useful after handover.\n\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003eBetter comfort control with less manual intervention\u003c\/li\u003e\n  \u003cli\u003eEnergy savings through responsive heating and cooling\u003c\/li\u003e\n  \u003cli\u003eCleaner handover with less “how does this actually run?” confusion\u003c\/li\u003e\n  \u003cli\u003eScalable retrofits across floors, wings, or entire portfolios\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr\u003e\n\n\u003ch2\u003eHow this fits into a Ready For Anything® solution\u003c\/h2\u003e\n\n\u003cp\u003e\nOn its own, MC-LW-FCT-01 delivers modern fan coil control with local visibility.\nWhen combined with the right LoRaWAN architecture, Niagara integration, data structure, and operator training, it becomes part of a Ready For Anything® solution — designed to keep delivering value long after commissioning.\n\u003c\/p\u003e\n\n\u003chr\u003e\n\n\u003ch2\u003eWho this product is for\u003c\/h2\u003e\n\n\u003cp\u003e\u003cstrong\u003eDesigned for\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSystem integrators modernising fan coil control at scale\u003c\/li\u003e\n  \u003cli\u003eHotels, residential, and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eFacilities teams seeking usable room-level control\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eNot ideal for\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eProjects driven purely by lowest upfront cost\u003c\/li\u003e\n  \u003cli\u003eInstallations with no integration strategy\u003c\/li\u003e\n  \u003cli\u003eSystems designed with no plan beyond handover\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr\u003e\n\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eHotels and hospitality rooms\u003c\/li\u003e\n  \u003cli\u003eResidential apartments\u003c\/li\u003e\n  \u003cli\u003eCommercial office buildings\u003c\/li\u003e\n  \u003cli\u003eSmart building retrofit projects\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr\u003e\n\n\u003ch2\u003eInstallation overview (from the user manual)\u003c\/h2\u003e\n\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e Installation involves mains voltage. The device should be installed only by a qualified electrician and only when the system is disconnected from the electrical supply. Do not mount the device on a metallic surface, and mount indoors only in a clean, dry place (no drip\/splash water). Use an external primary isolating facility and ensure appropriate overcurrent protection.\u003c\/p\u003e\n\n\u003col\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCommission on your LoRaWAN Network Server (recommended first):\u003c\/strong\u003e Add the device using the supplied Serial Number, DevEUI, AppEUI (JoinEUI) and AppKey from the credentials file. Once powered, it initiates a join procedure (SF12). Enable ADR in your LNS and\/or mark the device as static.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower off the existing thermostat:\u003c\/strong\u003e Turn off the power supply to the existing thermostat and remove it \u003cstrong\u003ewithout disconnecting the cables\u003c\/strong\u003e (they can help identify wiring).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIdentify the correct wiring diagram:\u003c\/strong\u003e Determine which FCU wiring configuration applies (2-pipe\/4-pipe, 3-speed\/ECM, etc.) and plan wiring accordingly.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRemove the power module:\u003c\/strong\u003e Lift the power module from the FCT (a flat screwdriver can help).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWire the terminals:\u003c\/strong\u003e Connect wires according to the chosen wiring diagram. Do not leave stranded wires or exposed metal outside the terminal. Tightening torque guidance applies to screw terminals.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eReinsert power module and restore power:\u003c\/strong\u003e Reinsert the power module into the FCT and restore power using the breaker.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnter Installer’s menu and select wiring configuration:\u003c\/strong\u003e Turn the device off (hold the M button for 3 seconds), then hold the reset button (back) and the fan speed button for 5 seconds. Select the correct wiring diagram for your application.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Mount the wall mounting plate using the included screws (and dowels if needed). Slide the thermostat onto the mounting plate and tighten the security screw on the bottom. Do not use non-flat head screws for the mounting bracket.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eValidate operation:\u003c\/strong\u003e Confirm the FCU responds correctly to mode changes, fan speed changes, and target temperature adjustments.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaintenance note:\u003c\/strong\u003e Check the electrical connections every 6 months and tighten if needed.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003chr\u003e\n\n\u003ch2\u003eTechnical details\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWireless technology:\u003c\/strong\u003e LoRaWAN® 1.0.3\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDevice type:\u003c\/strong\u003e Class C end-device\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower supply:\u003c\/strong\u003e 110–240VAC, 50\/60Hz\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMax consumption:\u003c\/strong\u003e 50mA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSensors:\u003c\/strong\u003e Temperature \u0026amp; humidity\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating conditions:\u003c\/strong\u003e 0°C to +50°C; 0–80% RH (non-condensing)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIP rating:\u003c\/strong\u003e IP31 (EN60529), indoor use\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 105 × 115 × 23 mm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaterials:\u003c\/strong\u003e ABS, PC, stainless steel\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting options:\u003c\/strong\u003e Screws and dowels on a wall or screws only on an electrical box; anti-theft bracket with secure screw (T5 Torx)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr\u003e\n\n\u003ch2\u003eDocumentation\u003c\/h2\u003e\n\u003cp\u003e\n\u003ca href=\"https:\/\/www.mclimate.eu\/wp-content\/uploads\/MClimate-FCT-Datasheet.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\nDownload the MC-LW-FCT-01 datasheet\n\u003c\/a\u003e\n\u003c\/p\u003e\n\n\u003cp\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1144\/2302\/files\/MClimate-FCT-User-Manual.pdf?v=1769673615\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\nDownload the MC-LW-FCT-01 User Manual\n\u003c\/a\u003e\n\u003c\/p\u003e\n\n\u003chr\u003e\n\n\u003ch2\u003eReady to discuss your project?\u003c\/h2\u003e\n\n\u003cp\u003e\nIf you’re planning a fan coil retrofit or want to understand how this fits into a wider \u003cstrong\u003eReady For Anything® solution\u003c\/strong\u003e, start a conversation with Innon.\n\u003c\/p\u003e\n\n\u003cscript src=\"https:\/\/js.hsforms.net\/forms\/embed\/5694023.js\" defer\u003e\u003c\/script\u003e\n\u003cdiv class=\"hs-form-frame\" data-region=\"na1\" data-form-id=\"8feb1a55-7168-493e-ad2b-28a7bbdb648e\" data-portal-id=\"5694023\"\u003e\u003c\/div\u003e\n","brand":"MClimate","offers":[{"title":"Default Title","offer_id":56519050625402,"sku":"MC-LW-FCT","price":201.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1144\/2302\/files\/MC-LW-FCT.png?v=1769610700","url":"https:\/\/www.innon.com\/en-de\/products\/mclimate-fan-coil-thermostat-mc-lw-fct","provider":"Innon Energy LTD","version":"1.0","type":"link"}