{"product_id":"isma-b-mac36nl-rs-50","title":"iSMA-B-MAC36NL-RS-050","description":"\u003cp\u003e\u003c\/p\u003e\n \u003ch5\u003eAbout the product\u003c\/h5\u003e\n \u003cp\u003eThe iSMA-B-MAC36NL is Niagara controller with 36 onboard IO and license of 50 points andtwo RS485 port. If more points are needed then you can upgrade in 50 points increment.\u003c\/p\u003e\n \u003cp\u003eThe MAC (Master Application Controller) with built-in different types of I\/O and operating in the Niagara Framework environment. Using the specific local I\/O set 16x UI, 8x AO, 4xDI and 8x DO allow to use the device in different applications. The controller provides control, data logging, alarming, scheduling, integration and visualisation.\u003c\/p\u003e\n \u003cp\u003eTo allow IP connectivity there are 2x Fast Ethernet ports which can operate as two independent ports. Built-in 2x RS485 can be used to expand number of I\/O by connecting MINI or MIX series I\/O modules or to integrate with other subsystems.\u003cbr\u003eiSMA-B-MAC36NL provides rich graphical interface displaying on a standard Web browser or on external display connected to built-in HDMI and USB port (touch-screen support).\u003cbr\u003e\u003cspan\u003eThere are two more hardware versions of the controller available: standard\u003c\/span\u003e\u003cstrong\u003eiSMA-B-MAC36NL\u003c\/strong\u003e\u003cspan\u003eand with\u003c\/span\u003e\u003cstrong\u003eM-Bus interface\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n \u003cp\u003e\u003c\/p\u003e\n \u003cp\u003eThe Niagara versions available for this controller in the latest \u003ca href=\"https:\/\/downloads.innon.com\/isma#main-contentiSMA-B-MAC36\/Niagara\/\"\u003eInstaller\u003c\/a\u003eversion:\u003c\/p\u003e\n \u003cul\u003e\n \u003cli\u003eNiagara 4.4.73 (not recommended)\u003c\/li\u003e\n \u003cli\u003eNiagara 4.4.92 (not recommended)\u003c\/li\u003e\n \u003cli\u003eNiagara 4.6.96.28 (Use the installer v1.9)\u003c\/li\u003e\n \u003cli\u003eNiagara 4.7.109.20 (Use the installer v1.9)\u003c\/li\u003e\n \u003cli\u003eNiagara 4.8.0.110 (Use the installer v1.9)\u003c\/li\u003e\n \u003cli\u003eNiagara 4.9.0.198 (Use the installer v1.4)\u003c\/li\u003e\n \u003cli\u003eNiagara 4.9.1.30 (Use the installer v1.9)\u003c\/li\u003e\n \u003cli\u003eNiagara 4.10.0.154(Use the installer v1.5)\u003c\/li\u003e\n \u003cli\u003eNiagara 4.10.1.36(Use the installer v1.7)\u003c\/li\u003e\n \u003cli\u003eNiagara 4.10.3.20 (Use the installer v1.9)\u003c\/li\u003e\n \u003cli\u003eNiagara 4.11.1.16 (Use the installer v1.9)\u003c\/li\u003e\n \u003cli\u003eNiagara 4.12.0.156 (Use the installer v1.8)\u003c\/li\u003e\n \u003cli\u003eNiagara 4.12.2.16 (Use the installer v1.9)\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eNiagara 4.10.7.42.1\u003c\/li\u003e\n \u003cli\u003eNiagara 4.10.9.14.1\u003c\/li\u003e\n \u003cli\u003eNiagara 4.13.2.18\u003c\/li\u003e\n \u003cli\u003eNiagara 4.14.0.162\u003cbr\u003e\n \u003c\/li\u003e\n \u003c\/ul\u003e\n \u003cul\u003e\u003c\/ul\u003e\n \u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n \u003cul\u003e\n \u003cli\u003eBACnet MSTP, Data Recovery Service, Web Service Ports fix and HDMI function are now available for N4.6 and higher.\u003c\/li\u003e\n \u003c\/ul\u003e\n \u003cp\u003e\u003cspan\u003eFor all new features and improvements, please see the\u003c\/span\u003e\u003ca href=\"https:\/\/downloads.innon.com\/isma#main-contentiSMA-B-MAC36\/Release_Note\"\u003eRelease Notes\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n \u003cp\u003e\u003c\/p\u003e\n \u003ch3\u003e\u003cstrong\u003eMain features\u003cbr\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n \u003cdiv class=\"row\"\u003e\n \u003cdiv class=\"col-sm-6\" style=\"text-align: justify;\"\u003e\n \u003cstrong\u003e16x Universal Inputs (16UI)\u003c\/strong\u003e\n \u003cp\u003eAll Universal Inputs have 16-bit ADC which support the following types of inputs:\u003cbr\u003eTemperature input supports the following types of sensors:\u003cbr\u003e10K3A1, 10K4A1, Carel 10K, 20K6A1, 2.2K3A1, 3K3A1, 30K6A1, SIE1, TAC1, SAT1, Pt1000, Ni1000\u003c\/p\u003e\n \u003cul\u003e\n \u003cli style=\"list-style-type: none;\"\u003e\n \u003cul\u003e\u003c\/ul\u003e\n \u003c\/li\u003e\n \u003c\/ul\u003e\n \u003cp\u003e\u003cstrong\u003eFor sensors Pt1000 and Ni1000 use only 16-bit resolution!\u003c\/strong\u003e\u003c\/p\u003e\n \u003cul\u003e\n \u003cli\u003eVoltage input 0-10 V DC: input resistance 100 k accuracy 0,1%, measurement resolution 3 mV @ 12-bit\u003cbr\u003eand 1 mV @ 16-bit\u003c\/li\u003e\n \u003cli\u003eCurrent input 0-20 mA (external resistor200 required)\u003c\/li\u003e\n \u003cli\u003eResistive input 0-1000 k: measurement resolution\u003cbr\u003efor 20 k load: 20 @ 12-bit and 1 @ 16-bit\u003c\/li\u003e\n \u003cli\u003eDry contact input\u003c\/li\u003e\n \u003c\/ul\u003e\n \u003cstrong\u003e4x Digital Inputs (4DI)\u003c\/strong\u003e\n \u003cul\u003e\n \u003cli\u003eDry contact inputs\u003c\/li\u003e\n \u003cli\u003eFast pulse counter up to 100 Hz saved in SD Card\u003c\/li\u003e\n \u003c\/ul\u003e\n 8x Analog Outputs (8AO)\n \u003cp\u003eAll Analog Outputs are equipped with 12-bit ADC provides 10 mV resolution and accuracy less than 0,5%. They support the following output types:\u003c\/p\u003e\n \u003cul\u003e\n \u003cli\u003eVoltage: 0-10 V DC max. load up to 20 mA\u003c\/li\u003e\n \u003cli\u003ePWM: 0,01 Hz, 0,1 Hz, 1 Hz, 10 Hz, 100 Hz\u003c\/li\u003e\n \u003c\/ul\u003e\n \u003cstrong\u003e8x Digital Outputs (8DO) \u003c\/strong\u003e\n \u003cul\u003e\n \u003cli\u003eRelay output (NO): max. 3 A @ 30 V DC\u003c\/li\u003e\n \u003c\/ul\u003e\n \u003c\/div\u003e\n \u003cdiv class=\"col-sm-6\"\u003e\n \u003cstrong\u003ePlatform\u003c\/strong\u003e\n \u003cul\u003e\n \u003cli\u003eMulticore Cortex-A Series ARM Processor\u003c\/li\u003e\n \u003cli\u003e1GB DDR3 SDRAM\u003c\/li\u003e\n \u003cli\u003eRemovable micro-SD card 4 GB\u003cbr\u003e(2 GB system reserved \/ 2 GB user storage)\u003c\/li\u003e\n \u003c\/ul\u003e\n \u003cstrong\u003eCommunication \u003c\/strong\u003e\n \u003cul style=\"text-align: justify;\"\u003e\n \u003cli\u003eRS485 half-duplex, opto-isolated\u003c\/li\u003e\n \u003cli\u003eBaud rate from 2400 to 115200\u003c\/li\u003e\n \u003cli\u003e2x Fast Ethernet (independent)\u003c\/li\u003e\n \u003cli\u003e2x USB (1x OTG, 1x Host)\u003c\/li\u003e\n \u003cli\u003eHDMI type A (standard)\u003c\/li\u003e\n \u003cli\u003eMicro SD card slot\u003c\/li\u003e\n \u003cli\u003eModbus RTU\/ASCII\/IP, BACnet MSTP\/IP, oBIX, SNMP,\u003cbr\u003eLON\/IP, KNX\/IP\u003c\/li\u003e\n \u003cli\u003eSecond RS485\u003c\/li\u003e\n \u003c\/ul\u003e\n \u003cstrong\u003ePower supply \u003c\/strong\u003e\n \u003cul style=\"text-align: justify;\"\u003e\n \u003cli\u003e24 V AC\/DC\u003c\/li\u003e\n \u003c\/ul\u003e\n \u003cstrong\u003eHousing\u003c\/strong\u003e\n \u003cul style=\"text-align: justify;\"\u003e\n \u003cli\u003eDimensions: 160x110x62 mm.\u003c\/li\u003e\n \u003cli\u003eConstruction: UL approved,\u003cbr\u003eself-extinguishing plastic (PC\/ABS)\u003c\/li\u003e\n \u003cli\u003eDIN rail mounting DIN (DIN EN 50022 norm)\u003c\/li\u003e\n \u003cli\u003eCooling: internal air circulation\u003c\/li\u003e\n \u003c\/ul\u003e\n \u003cstrong\u003eEnvironment\u003c\/strong\u003e\n \u003cul\u003e\n \u003cli style=\"text-align: justify;\"\u003eOperating temperature: -10C to 50C\u003c\/li\u003e\n \u003cli style=\"text-align: justify;\"\u003eStorage temperature: -40C to 85C\u003c\/li\u003e\n \u003cli style=\"text-align: justify;\"\u003eRelative humidity: 5% to 95%, no condensation\u003c\/li\u003e\n \u003cli style=\"text-align: justify;\"\u003eIngress Protection Rating: IP40 for indoor installation\u003c\/li\u003e\n \u003c\/ul\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003ch5\u003e\n \u003ca href=\"https:\/\/downloads.innon.com\/isma#main-contentiSMA-B-MAC36NL\/\"\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/a\u003e\n\u003c\/h5\u003e\n \u003cdiv class=\"row row-2\"\u003e\n \u003cdiv class=\"row row-2\"\u003e\n \u003cdiv class=\"row row-2\"\u003e\n \u003cdiv class=\"row row-2\"\u003e\n \u003cdiv class=\"row row-2\"\u003e\n \u003cdiv class=\"row row-2\"\u003e\n \u003cdiv class=\"row row-2\"\u003e\n \u003cdiv class=\"row row-2\"\u003e\n \u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n \u003cdiv class=\"question-ship-block\"\u003e\n \u003cdiv\u003e\n \u003ch4\u003eProduct Informations\u003c\/h4\u003e\n \u003cp\u003e\u003c\/p\u003e\n \u003cdiv class=\"row row-1\"\u003e\n \u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n \u003cdiv class=\"question-ship-block\"\u003e\n \u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat is the default IP of the device?\u003c\/span\u003e\u003c\/h4\u003e\n \u003cdiv class=\"qs-content\"\u003eThe default IP is : 192.168.1.123.\u003c\/div\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003cp\u003e\u003c\/p\u003e\n \u003cp\u003e\u003c\/p\u003e\n \u003cdiv class=\"row row-1\"\u003e\n \u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n \u003cdiv class=\"question-ship-block\"\u003e\n \u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat Niagara version is needed to connect to this controller?\u003c\/span\u003e\u003c\/h4\u003e\n \u003cdiv class=\"qs-content\"\u003eAt the moment thedefault Niagara version is N4.4 (4.4.73.24).\u003c\/div\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003cp\u003e\u003c\/p\u003e\n \u003cdiv class=\"row row-1\"\u003e\n \u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n \u003cdiv class=\"question-ship-block\"\u003e\n \u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat should I do if I need to use Niagara 4.4.92.2?\u003c\/span\u003e\u003c\/h4\u003e\n \u003cdiv class=\"qs-content\"\u003eTo install dist you can either copy the \u003ca href=\"https:\/\/downloads.innon.com\/isma#main-contentiSMA-B-MAC36NL\/Niagara\/Precious%20Versions\/iSMA-MAC36_nre_4.4.92.2\/\"\u003eDIST FILES\u003c\/a\u003e\u003ca href=\"https:\/\/downloads.innon.com\/isma#main-contentiSMA-B-MAC36NL\/Niagara\/iSMA-MAC36_nre_4.4.92.2\/\"\u003e \u003c\/a\u003eto your\u003cbr\u003e%HOMEPATH%\\Niagara4.4\\sw\\inbox folder and use commisioning wizard, or use PlatformDistribution File Installer, choose file and install.\u003c\/div\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003cp\u003e\u003c\/p\u003e\n \u003cdiv class=\"row row-1\"\u003e\n \u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n \u003cdiv class=\"question-ship-block\"\u003e\n \u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat should I do if I need to use Niagara 4.6, 4.7 or 4.8?\u003c\/span\u003e\u003c\/h4\u003e\n \u003cp\u003ePlease download thelatest update files\u003ca href=\"https:\/\/downloads.innon.com\/isma#main-contentiSMA-B-MAC36NL\/Niagara\/\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eHERE\u003c\/span\u003e\u003c\/a\u003e, into the zipfile, which contains the DIST files for version 4.6, 4.7 and 4.8. You will find a file named iSMA_MAC36_files_installer_v1.0.1152.bat, this will copy for you all the DIST files into the relevant folders. After this procedure you will need to restart the Workplace and commission your MAC36NL with the 4.6, 4.7 or 4.8 version.\u003c\/p\u003e\n \u003cp\u003e\u003cspan\u003eIf you need to upgrade to 4.8\u003c\/span\u003e\u003cspan\u003eand\u003c\/span\u003e\u003cspan\u003ethe controller is already running onlower versions (4.4, 4.6or 4.7) the first step you will need\u003c\/span\u003e\u003cspan\u003eto do is\u003c\/span\u003e\u003cspan\u003eto clean the controllerby installing the CleanDist file using the Distribution\u003c\/span\u003e\u003cspan\u003eF\u003c\/span\u003e\u003cspan\u003eile\u003c\/span\u003e\u003cspan\u003eI\u003c\/span\u003e\u003cspan\u003enstaller from the controller's platform and after that commission the MAC36NL controller with the 4.8.\u003c\/span\u003e\u003c\/p\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n \u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhatare theimprovements for the MAC36NLwithNiagara 4.6 and 4.7?\u003c\/span\u003e\u003c\/h4\u003e\n \u003cp\u003e\u003cspan\u003eWith the release of N4.6 and N4.7 for the MAC36NL you some new features:\u003c\/span\u003e\u003c\/p\u003e\n - BACnet MSTP -HDMI\u003cbr\u003e-Data Recovery Service -\u003cspan\u003eWeb Service Port Fix\u003c\/span\u003e\u003cbr\u003ePlease see read the \u003ca href=\"https:\/\/downloads.innon.com\/isma#main-contentiSMA-B-MAC36NL\/Release_Note\/iSMA-B-MAC36NL_Release_Notes.pdf\"\u003eRelease Notes\u003c\/a\u003e.\u003c\/div\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003cp\u003e\u003c\/p\u003e\n \u003cdiv class=\"row row-1\"\u003e\n \u003cdiv class=\"row row-1\"\u003e\n \u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n \u003cdiv class=\"question-ship-block\"\u003e\n \u003ch4\u003e\n \u003cspan style=\"color: #ff0000;\"\u003e\u003c\/span\u003e\u003cbr\u003e\n \u003c\/h4\u003e\n \u003cbr\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003cdiv class=\"row row-1\"\u003e\u003cbr\u003e\u003c\/div\u003e\n \u003cdiv class=\"row row-1\"\u003e\n \u003cdiv class=\"row row-1\"\u003e\n \u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n \u003cdiv class=\"question-ship-block\"\u003e\n \u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat are the default platform Credentials?\u003c\/span\u003e\u003c\/h4\u003e\n \u003cdiv class=\"qs-content\"\u003eThe default credentials are the same as to the Tridium controllers:\n \u003cp\u003e\u003c\/p\u003e\n \u003cp\u003eUser: tridium\u003c\/p\u003e\n \u003cp\u003ePassword:niagara\u003c\/p\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003cp\u003e\u003c\/p\u003e\n \u003cdiv class=\"row row-1\"\u003e\n \u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n \u003cdiv class=\"question-ship-block\"\u003e\n \u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat communication networks are available?\u003c\/span\u003e\u003c\/h4\u003e\n \u003cdiv class=\"qs-content\"\u003eIn this stage the Networks that work are:\n \u003cp\u003e\u003c\/p\u003e\n \u003cp\u003e- Modbus RS485\u003c\/p\u003e\n \u003cp\u003e- Modbus TCP\u003c\/p\u003e\n \u003cp\u003e- BACnet TCP\u003c\/p\u003e\n \u003cp\u003e- BACnet MSTP available for version N4.6 and N4.7.\u003c\/p\u003e\n \u003cp\u003e\u003cspan\u003e-Mbus TCP\u003c\/span\u003e\u003c\/p\u003e\n \u003cp\u003e- Niagara Network\u003c\/p\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003cp\u003e\u003c\/p\u003e\n \u003cdiv class=\"row row-1\"\u003e\n \u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n \u003cdiv class=\"question-ship-block\"\u003e\n \u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat features are implemented into this controller compared to the Tridium Jace?\u003c\/span\u003e\u003c\/h4\u003e\n \u003cdiv class=\"qs-content\"\u003eThe iSMA has the same features as a Tridium N4 controller:\n \u003cp\u003e\u003c\/p\u003e\n \u003cp\u003e-Alarm\u003c\/p\u003e\n \u003cp\u003e-Histories\u003c\/p\u003e\n \u003cp\u003e-PX pages (web User Interface pages) HTML 5 web viewing\u003c\/p\u003e\n \u003cp\u003e-Communication with Niagara controllers and Supervisors through Niagara Network\u003c\/p\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003cp\u003e\u003c\/p\u003e\n \u003cdiv class=\"row row-1\"\u003e\n \u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n \u003cdiv class=\"question-ship-block\"\u003e\n \u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhen commissioning I see this message: there is no Core software found that can be installed, what should I do?\u003c\/span\u003e\u003c\/h4\u003e\n \u003cdiv class=\"qs-content\"\u003eThe core software is installed from the factoryfor version 4.4.73, you just need to press Next.\u003c\/div\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003cp\u003e\u003c\/p\u003e\n \u003cdiv class=\"row row-1\"\u003e\n \u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n \u003cdiv class=\"question-ship-block\"\u003e\n \u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eAfter using the commissioning wizard to install the Station and modules, I can see into the Application Directory that there are errors regarding the Web Server and I cannot access the controller from the webpage. How do I resolve that error and access the controller through the web page?\u003c\/span\u003e\u003c\/h4\u003e\n \u003cdiv class=\"qs-content\"\u003eAt this stage the Web server works with the TCP port above 1024, so you will need to go and change the HTTP and HTTPs ports to be above 1024 (ex: HTTP port - 8080, HTTPs port 8443).\u003cspan\u003eAfter setting this up please restart the station. \u003cstrong\u003eThis issue was resolved in N4.6 and N4.7 release.\u003c\/strong\u003e\u003c\/span\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003cp\u003e\u003c\/p\u003e\n \u003cdiv class=\"row row-1\"\u003e\n \u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n \u003cdiv class=\"question-ship-block\"\u003e\n \u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eHow does the Local IOs work?\u003c\/span\u003e\u003c\/h4\u003e\n \u003cdiv class=\"qs-content\"\u003eThe Local IO driver it is still at an early stage and you will need to Download the\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/downloads.innon.com\/isma#main-contentiSMA-B-MAC36NL\/Niagara\/iSMAIO.zip\" style=\"color: #0000ff; text-decoration: underline;\"\u003eJar file.\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003ePut it into the Modules folder and restart the Workbench. Go and find the iSMA IO into the Palette.\u003c\/div\u003e\n \u003cdiv class=\"qs-content\"\u003eInto the Drivers add from the iSMA_IO Palette the iSMA IO Network, after that open the Property Sheet of the Drivers to see the recently added Network. Under it add the Local IO Device and under that add the points from the palette.\u003c\/div\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003cp\u003e\u003c\/p\u003e\n \u003cdiv class=\"row row-1\"\u003e\n \u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n \u003cdiv class=\"question-ship-block\"\u003e\n \u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eHow do I change the Universal Input type?\u003c\/span\u003e\u003c\/h4\u003e\n \u003cdiv class=\"qs-content\"\u003eOpen the property sheet of the UI and you will see the Input type property, by default it is set to Voltage.\u003c\/div\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003cp\u003e\u003c\/p\u003e\n \u003cdiv class=\"row row-1\"\u003e\n \u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n \u003cdiv class=\"question-ship-block\"\u003e\n \u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eHow do I change the Analog Output type?\u003c\/span\u003e\u003c\/h4\u003e\n \u003cdiv class=\"qs-content\"\u003eOpen the property sheet of the AO and you will see the Output type property, by default it is set to Voltage.\u003c\/div\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003cp\u003e\u003c\/p\u003e\n \u003cdiv class=\"row row-1\"\u003e\n \u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n \u003cdiv class=\"question-ship-block\"\u003e\n \u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eHow can I use the HDMI function?\u003c\/span\u003e\u003c\/h4\u003e\n \u003cdiv class=\"qs-content\"\u003e\n \u003cdiv class=\"qs-content\"\u003eAfter you have commissioned the controller on your N4.6 or N4.7 and install the iSMA_HDMI jar file, copy the HDMI service from the iSMA_HDMI pallette to the Service folder and you will need to go to the WEB service and activate the HTTP port and disable HTTPS Only. After you make those settings please reboot the controller.\u003c\/div\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003cp\u003e\u003cbr\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n \u003ca href=\"https:\/\/downloads.innon.com\/isma#main-contentiSMA-B-MAC36\" target=\"_blank\" title=\"Documentation \u0026amp; Downloads for iSMA-B-MAC36NL-RS-050\" rel=\"noopener\"\u003e\u003cimg src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" alt=\"Documentation \u0026amp; Downloads for iSMA-B-MAC36NL-RS-050 style=\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/downloads.innon.com\/isma#main-contentiSMA-B-MAC36NL\" title=\"Documentation \u0026amp; Downloads for iSMA-B-MAC36NL-RS-050\"\u003e \u003c\/a\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":57202902925690,"sku":"iSMA-B-MAC36NL-RS-050","price":1534.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1144\/2302\/files\/ISMA-B-MAC36-RS-600x600_936a61a7-bdd8-453c-b4fe-240bc8e8d527.png?v=1787663132","url":"https:\/\/www.innon.com\/products\/isma-b-mac36nl-rs-50","provider":"Innon Energy LTD","version":"1.0","type":"link"}