Not sure if this is right for your project?
Before you spec it, talk to an engineer. We'll tell you honestly whether this product is the right call — and if it isn't, we'll point you to one that is. Free. No obligation.
Get a free project consultation →TEKTELIC BREEZE-V with E-Ink Display — LoRaWAN IAQ & Occupancy Sensor
← TEKTELIC at INNON® / BREEZE-V + Display
Technical Documents
Everything you need before and after commissioning.
Spec sheet, user guide, and integration resources — all hosted directly so you can share links with your team or drop them into your project documentation.
Spec Sheet
Full specs — CO2, PIR, display, battery life, RF performance.
Download PDF →
User Guide
Commissioning — PIR setup, display pairing, LoRaWAN onboarding.
Download PDF →
INNON® Support
Talk to us about demand-controlled ventilation strategies for your project.
Ask our team →
Missing a document?
CE declarations, LoRa Alliance certifications, and firmware release notes available on request.
A Ready For Anything® building block
Full IAQ and occupancy monitoring with an E-Ink display showing live CO2 and temperature. Single device, single installation, maximum visibility.
CO2 · PIR · Temperature · Humidity · VOC · Light · E-Ink display · CF25 compliant · LoRaWAN EU868
All the BREEZE-V capability, with visible occupant feedback
Everything in the BREEZE-V — CO2, PIR, temperature, humidity, VOC, light — plus the E-Ink display showing live CO2 and temperature to room occupants. In a school or office, occupants can see the air quality. In a meeting room, facilities managers can demonstrate compliance without pulling up a dashboard.
BACnet output unchanged — Niagara still receives all data points regardless of what the display shows.
Technical Specifications
Key parameters at a glance.
| CO2 range | 0 – 5,000 ppm (NDIR) |
| Occupancy | PIR passive infrared |
| Display | E-Ink, CO2 and temperature |
| Temperature / Humidity / VOC / Light | All included |
| Battery life (sensor) | 10 years |
| LoRaWAN class | Class A |
| Frequency band | EU868 |
| CF25 compliant | Yes |
Pre-Sales Support Included
Not sure if this product fits your project?
Talk to one of our engineers before you order. We've commissioned this hardware on real sites — we know where it works, where it doesn't, and what you'll need alongside it.
Talk to an engineer →Why the BREEZE-V with E-Ink Display is Ready For Anything®
🟢 Ready for Today
- CO2, temperature, humidity, pressure, VOC, PIR — plus a live E-Ink display — air quality, presence, and environment from one device; occupants read live CO2 and temperature directly without a dashboard login
- PIR plus CO2 for demand-controlled ventilation — the two inputs your AHU control logic needs for genuine occupancy-led ventilation, from one device, one LoRaWAN slot
- Display bridges BMS and building users — staff act on CO2 levels from the sensor face without facilities dashboard access; reduces complaints and HVAC override requests
- Battery powered, no wiring — install anywhere; no cable, no electrician, no BMS input card change
🔵 Ready for Change
- One device replaces three — occupancy sensor, air quality transmitter, and occupant display combined; fewer LoRaWAN slots, fewer BACnet addresses, cleaner infrastructure
- Relocatable — battery powered; move the measurement point as the space use changes without rewiring
🔐 Ready for Security
- AES-128 LoRaWAN encryption — all sensor data encrypted end to end from device to KONA gateway
- No cloud dependency — BACnet values delivered to Niagara via KONA embedded LNS; no external server or internet connection required
🔗 Ready for Integrations
- BACnet output via KONA embedded LNS — CO2, temperature, humidity, pressure, VOC, and PIR all mappable as individual BACnet objects in Niagara
- LoRaWAN Class A — EU868, US915 — pairs with TEKTELIC KONA Micro or Enterprise gateways
- INNON-tested integration — commissioned in Niagara; documented at know.innon.com
A few things worth knowing before you deploy
- Automatic CO2 self-calibration — recalibrates on a configurable schedule (7 days by default); no manual reset required, no drift over time, no site visit after installation
- Barometric pressure compensation — CO2 readings corrected for altitude and local air pressure; consistent accuracy across different floor levels without manual offset calibration
- E-Ink display and sensor in one body — no separate display unit to mount, power, or configure; one device covers measurement, occupancy, and occupant-readable feedback from a single wall mounting
- Display retains last reading without power — E-Ink is bistable; if the battery drains, the last CO2 and temperature reading stays visible on screen; the display does not go blank
- 10 year battery life — deploy once; no battery replacement programme for a sensor that also carries a display
For commissioning support or bulk pricing contact sales@innon.co.uk.