iSMA-B-AAC20-LCD-D

BMS Controller

iSMA-B-AAC20-LCD-D

  • Brand:iSMA
  • Category: All Products, BMS Controllers, GreenBox 360 Compatible, HVAC BMS Controls, iSMA Range, Lighting Control IO Modules, Sedona BMS Controls
Availability: In Stock
£782.00 GBP
Best price only when you register / login. Takes just 7 seconds

AAC20 controller (iSMA-B-AAC20) with inbuilt display and DALI is an advanced device to control building automation and HVAC systems. Use of SVM (Sedona Virtual Machine) allows you to finish the setup quickly and easily. It is ideal for smaller projects where you want to stay open protocol while keeping the development simple and the cost under budget.

Big, fully programmable LCD can be used as simple user interface to allows local operation of system. The DALI Interface with built-in power supply.

With the large number of inputs and outputs allows to integrate with other devices and sensors (AAC20 provides 8xUI, 4xDI, 4/6xAO and 4xDO). Its fast processor allows to control of even very large objects. Built-in RS485 can be used to expand number of I/O by connecting MINI or MIX series I/O modules using Modbus ASCII/RTU. In addition, to increase the versatility of the controller, it supports many open communications protocols like: BACnet, Modbus, SOX, DALI, M-Bus, 1-wire or oBIX (optional). AAC20 is mounted in a housing adapted for DIN rail mounting or directly on a panel. Separate, easy to remove connectors allow quick wiring without removing the entire module.

Inputs & Outputs
8xUniversal Inputs (8UI)
All universal inputs have 16-bit resolution which support the following types of inputs:
  • Temperature input support the following types of sensors: 10K3A1, 10K4A1, Carel 10K, 20K6A1, 2.2K3A1, 3K3A1, 30K6A1, SIE1, TAC1, SAT1, Pt1000, Ni1000
For sensor Pt1000 and Ni1000 use only 16bit resolution
  • Voltage input 0-10VDC: input resistance 100kΩ accuracy ±0,1% measurement resolution 3mV@12bit and 1mV@16bit
  • Current input 0-20mA (external resistor 499Ω required)
  • Resistive input 0-1000kΩ: measurement resolution for 20kΩ load 20Ω@12bit and 1Ω@16bit
  • Dry contact input
4 x Digital Inputs (4DI)
  • Dry contact inputs
  • Fast pulse counter up to 100Hz
4/6 x Analog Outputs (4/6AO)
All analog outputs are equipped with 12-bit ADC provides10 mV resolution and accuracy less than ±0,5%. They support the following output types:
    • Output 0-10V DC maximum load up to 20mA(5mA- AO6)
    • PWM: 0,01Hz, 0,1Hz, 1Hz, 10Hz, 100Hz
AO5 and AO6 can only be used if 1-wire port is not in use, please notice for AO6 maximum current load is up to 5mA
4 x Digital Outputs (4DO)
  • Relay output (NO) max. 3A, 250 VAC/30 VDC
Platform
  • ARM Cortex-M4 204MHz
  • ARM Cortex-M0 204MHz
Communication
  • Interface RS485 half duplex
  • Baud rate: 2400 to 115200 bps
  • 2xEthernet with built in switch
  • 1-Wire Interface
  • Micro SD card slot
  • USB Host Interface
  • Protocols: Modbus, BACnet, 1-wire, oBIX
Power supply
  • 24V AC/DC
Housing
  • Dimension: 106x110x62 mm.
  • Construction: plastic, self-extinguishing (PC/ABS)
  • DIN rail mounting (DIN EN 50022 norm)
  • Cooling: internal air circulation
Environments
  • Operating temperature: -10°C to 50°C
  • Storage temperature: -40°C to 85°C
  • Relative humidity: 5 to 95%, no condensation
  • Ingress Protection Rating: IP40 – for indoor installation

    Save time and find out what IO need for your project:

    Make sure you get the latest discounts and prices register here:

    Pdf 07203e634431f4d17e7c6c921cd94f1e9d74d1f6a670624fd1f197332e7ccd38 iSMA-B-AAC20-LCD-D Instalation instruction
    Pdf 07203e634431f4d17e7c6c921cd94f1e9d74d1f6a670624fd1f197332e7ccd38 iSMA-B-AAC20 Datasheet
    Pdf 07203e634431f4d17e7c6c921cd94f1e9d74d1f6a670624fd1f197332e7ccd38 iSMA-B-AAC20 User Manual Platform
    Pdf 07203e634431f4d17e7c6c921cd94f1e9d74d1f6a670624fd1f197332e7ccd38 iSMA-B-AAC20 Modbus
    Pdf 07203e634431f4d17e7c6c921cd94f1e9d74d1f6a670624fd1f197332e7ccd38 iSMA-B-AAC20 BACnet
    Pdf 07203e634431f4d17e7c6c921cd94f1e9d74d1f6a670624fd1f197332e7ccd38 iSMA-B-AAC20 LCD
    Pdf 07203e634431f4d17e7c6c921cd94f1e9d74d1f6a670624fd1f197332e7ccd38 iSMA-B-AAC20 DALI
    Pdf 07203e634431f4d17e7c6c921cd94f1e9d74d1f6a670624fd1f197332e7ccd38 iSMA-B-AAC20 Quick Engineering Guide
    iSMA-B-AAC20 Software Bundle
    Pdf 07203e634431f4d17e7c6c921cd94f1e9d74d1f6a670624fd1f197332e7ccd38 iSMA-B-AAC20 Release Note

    In the DOWNLOAD session you can find:
    The ISMA driver for Niagara, which contains the ISMA device Palette
    ISMA configurator which is needed for updating firmware and configure modules


    For any help please contact our support here

    Shipping Informations

    What Shipping Methods are Available?

    We do UK next day delivery and 2 working days for Ireland We do Europe standard 3 day delivery. We do Worldwide delivery between 2 and 7 days depending on each country.

    How Can I Return A Faulty Product?

    Returns are free of charge we will organize the pickup only in the case the product is faulty. Please contact support@innon.co.uk to obtain an RMA number first.

    How Do I Track My Order?

    Once we ship your order, you will receive a tracking number and you will also find it in My Account section.

    How can I place an Order?

    You can place an order online and pay by credit/debit card if you do not have a Trading Account.
    You can please your order online and pay by Trading Account if you have a Business Trading Account.
    To open a Business Trading Account please fill in this form and send it back to office@innon.co.uk

    Customer Reviews

    Based on 1 review Write a review